Chapter 16 Firmware Revision History
498
Firmware Version 3/4.31.37
Enhancement: Added new parameter Additive No Flow mA, this to support Analog
Additive Control Valve which needs continuous 4mA loop power.
Enhancement: Added on Bay Level Output Pulse Type for Gross, Net and Mass.
12/04/2014 PS
Fix: The 6 character CTL, CPL and VCF fields on the MRTD, MRS and R800 commands
were incorrectly reporting values as 0.09883 instead 0.98830 when 1980 API-Tables
were selected.
Enhancement: Added No Flow Analog Control Valve parameter to set the loop
current when the valve is to remain closed.
Increased FCM Version to 42.
12/07/2014 PS
Fix: The increase and decrease mA value for an analog valve was previously sent
to the FCM as a mA value instead of a percentage value.
Remark: After upgrading the ML firmware, it is necessary to check the control
behavior of the analog valve since adjustments will now occur twice as fast.
Enhancement: Display Load Volume can be configured to show Gross, Net or Mass
values.
Enhancement: Total Net Vol and Total Mass Vol can be read in custom logic.
12/10/2014 PS
Fix: Custom Prompting in UAP mode will now support decimal numbers.
12/11/2014 TF
Fix: Observed Values Prompts issue. The MultiLoad would still prompt for the
observed values even if the load was cancelled.
Fix: Transaction viewer issue. The viewer wouldn't show the observed density,
because the MultiLoad wasn't saving the density type in the detail.
12/12/2014 MS
Enhancement: Added UAPGATE as a product selection. Simple 5 sec gate stimulus
from Load Authorization FCM output.
12/13/2014 PS
Enhancement: Change layout of W&M Voucher, Unauthorized Flow Voucher, End Of Day
Report.
Alibilog labels are hardcoded now, only prompt 1 to prompt 5 can be still
configured.
Enhancement: Added PTB Diagnostic Screen.
12/15/2014 PS
Fix: In very rare condition it was possible that the clear of a batch was out of
sync.
12/16/2014 PS
Fix: SIGNED_DIV1000 print value.
Enhancement: Added for Alibilog and PTB Printers the option to print all
parameters or only W&M parameters.
12/17/2014 TF
Fix: Couldn't clear certain alarms if a Preset was disabled and was sharing a FCM
with another Preset.
01/04/2015 PS
Change Alibilog Label register from 706 to 707.
01/14/2015 TF