Chapter 16 Firmware Revision History
507
Firmware Version 3/4.31.37
Updated BSW, RTD, Pressure, Density, Relative Density and API Gravity to use new FCM
Analog Input Type.
Removed seperate enable parameter for many of these parameters.
Added SCS I/O Board Calibration Screen to Factory Menu.
Added common routine to display RTD and 4-20mA status to simplify code.
Updated configuration report to report the analog input port #.
Added new FCM structs for up to 4 analog ports.
Added simulation code for up to 4 analog ports.
Updated named references from integers to struct fcm_address_analog_input to simplify
code.
Renamed 4ma and 20ma variables and parameter names to low_value and high value to support
both ma and V interfaces. Also updated help files for new parameter names.
Updated configuration checking to check for analog input and output assignment errors.
New fcm_address_analog_input parameters can also reference a custom logic line instead of
FCM analog port.
Added checks to verify that RTD, Pressure, Density, Relative Density and API Gravity are
assigned to valid FCM numbers.
Corrected bug in checking that when temperature module numbers 10 or over are assigned to
a valid FCM number.
Corrected bug where configured port number not checked at startup against max port
number.
9/29/2015 WJP
Updated named references from integers to union internal_fcm_address_type to simplify
code.
Fixed bug with external encoding of custom logic lines into external_fcm_address values.
Fixed bug with audit log level registing of modbus changes to alarm output assignments
for meters.
9/30/2015 TF
Fix: Alibilog routine. If there were more than 7 alarms, and the 8th alarm was an
Additive alarm, we could potentially overflow the buffer which would cause a blue screen.
Fix: Alternative High Flow rate. If two components were sharing one meter, when the
alternative high flow input was triggered, we would configure the FCM incorrectly.
Updated the FCM mapping report to use the new analog fcm input type.
10/1/2015 TF
Added SCS I/O Board to FCM Types
10/13/2015 WJP
Added display of Ohms or mA input value on views and inquiries screens for Temperature,
Density, Rel. Density, Gravity, Pressure, and BSW.
Updated preset status screen to always display the live BSW since this is a preset level
input and not averaged between components or meters.
Updated SCS factory calibration screen to only show available analog ports for each
processor.
11/2/2015 TF
Fix: The Login Screen wouldn't timeout if no keypress was generated after x number of
minutes.
Fix: The Reports Menus wouldn't timeout if no keypress was generated after x number of
minutes.
Added the display of divert status to the Preset Status and Component Status screens.
Added the ability to send Modbus commands to other devices:
- Commands are configurable in Custom Logic: READ16, READ32, WRITE16, and WRITE32
- Configure up to 10 Modbus Devices.