Chapter 16 Firmware Revision History
506
Firmware Version 3/4.31.37
Enhancement: The formatting of the Audit and W&M Change logs to display the Username when
the displaying the logs on the web interface. Previously was only doing that
for the SD Card.
Enhancement: (Available for ALL reports) Once a report has finished being generated, a
summary of the report will be displayed on the screen. This summary can be
sent to a printer if one is configured.
Fix: The formatting of the strings used for printing security parameters in the Audit and
W&M Change logs.
Fix: Log message for "OVER ADD ALARM PERCENTAGE". A "<" was used instead of a ">".
Fix: Converted SCS screens and reports to use GOV and GSV instead of Gross and Net.
Fix: Audit Log and W&M Change log would display the wrong user number when printing
Security Account changes.
Fix: SD Card formatter was broken.
Fix: Display of DHCP Gateway, and Subnet Mask.
Made some modifications to the transactions_archive_read() routine. Needed to convert the
input parameter "address" from an unsigned int* to a void* in order for it to work
correctly for RHEL7.
08/31/2015 TF
Increased the number of User Accounts from 9 to 10
09/01/2015 TF
Added the ability to load a prompt_script.LUA file from the SD Card to be used when UAP
is configured. When the MultiLoad is first powered up, it will scan the home directory of
the SD Card for a "prompt_script.LUA" file. Which can be used to customize the prompts that
are displayed to the Driver when they card in.
Added ".txt" extensions to all log files.
09/02/2015 TF
Fix: BSW Averaging of values that are below 0 and above 100
Fix: Default Relative Density. If Default Relative Density was set, the MultiLoad
wouldn't use the value unless the Default Density was configured.
Fix: The background and foreground of the Bottom Help bar were being displayed
incorrectly after returning from the Help screens (Only when scrolling through the help
text at the bottom).
09/03/2015 TF
Fix: When Open Load was configured, it would print an UNAUTHORIZED FLOW VOUCHER to the
alibilog printer if some flow occured when the preset wasn't authorized to flow product.
However, if a driver then went to authorize another load and the unauthorized flow amount
never triggered an alarm, the previous unauthorized flow volume wouldn't get cleared and it
would appear on the new transaction ticket.
9/18/2015 TF
Increased firmware version to x.31.27
9/23/2015 WJP
Updated latest known FCM version to 44 (with interface to support up to 4 analog ports
per FCM).
Added new FCM_ADDRESS_ANALOG_INPUT format type.