Setting-Up Tests
Humphrey Field Analyzer II-
i
series User Manual 2660021145640 A
3-4
Test Library
The HFA II-
i
offers a variety of screening and threshold test patterns that meet most clinical needs.
Table 3.1 suggests which test strategies may be best suited
for specific disease categories. Table 3.2,
Table 3.3, and Table 3.4 describe each test pattern in order to assist you in choosing the one best
suited to the patient’s needs. Appendix (F), "Test Patterns" contains diagrams of all the available
test patterns.
Screening tests serve an important clinical function by quickly surveying the visual field and
flagging
areas that are highly suspect. They answer the question, “Is there a problem?” Abnormal test results
warrant additional threshold testing. See Table 3.2 for available Screening tests.
Threshold tests more precisely define the problem by calculating the actual sensitivity level at eac
h
test point. They uncover early depressions and subtle changes in retinal sensitivity. See Table 3.3 for
details about the various Threshold tests.
Specialty tests are specially designed scre
ening tests for specific purposes. See Table 3.4 for details
about the Specialty tests.
Models 740
i
, 745
i
and 750
i
allow you to create and store your own Custom test patterns. In
addition, the HFA II Model 750
i
offers Kinetic testing (optional on 740
i
and 745
i
). See Chapter (12),
"Custom Testing," and Chapter (13), "Kinetic Testing," for more information on these testing
options.
Table 3.1
Disease Category Test(s) Recommended
General Screening Central 64
a
, Central 76
Full Field 81, Full Field 120
Peripheral Screening Peripheral 60
Full Field Screening Full Field 81, Full Field 120
Glaucoma Suspect or Ocular Hypertension 30-2 SITA Standard or SITA Fast
24-2 SITA Standard or SITA Fast
24-2 SITA-SWAP
Glaucoma 30-2 SITA Standard or SITA Fast
24-2 SITA Standard or SITA Fast
24-2 SITA-SWAP
10-2 SITA for Advanced Glaucoma
Central 76, Nasal Step
a
Central Armaly
a
a. Not available on the HFA Model 720i.
, Armaly Full Field
a
Full Field 81, Full Field 120
Drug Toxicity 10-2
Neurological Damage Central 64
a
, Central 76
a
Full Field 81 or Full Field 120
Peripheral 60 (plus a central exam)
Macular Degeneration 10-2 SITA, Macula
Ptosis Superior 64, Superior 36
Quick Reference to Tests Applicable for Specific Disease Categories

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zeiss Humphrey II-i series and is the answer not in the manual?

Zeiss Humphrey II-i series Specifications

General IconGeneral
BrandZeiss
ModelHumphrey II-i series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals