9980 Self-Propelled Peanut Combine Electrical System Service
Battery Cables
When you connect batteries:
1. Turn off all switches and accessories.
2. Clean battery posts and terminals.
3.
QUICKLY TAP the ground strap to the
negative post. Arcing must not occur. If
arcing
occurs, DO NOT MAKE
CONNECTION. Check to see if the
battery position is reversed.
4.
If arcing still occurs, check again that all
switches and accessories are off, then
check for shorts, broken wires, and loose
or corroded connections.
5. Connect negative (-)
battery ground
straps.
CAUTION
BATTERIES ARE NEGATIVE
GROUNDED ONLY.
ALWAYS connect
battery ground strap to negative (-) posts
of battery. Connect starter cable to
positive (+) post of battery. Reversed
polarity in battery or alternator connections
results in permanent damage to the
electrical system. Connect ground strap to
negative (-) terminal last.
MAN141 09/04/15 245