9980 Self-Propelled Peanut Combine Diagnostic Codes
RCU: Control Unit RCU and Right Power Module
Control Unit SPN FMI Priority
Description
RCU 629 12 Service Alert
Control unit RCU has reset itself due to watchdog timer.
RCU 1075 03 Stop
Fuel transfer pump (cc# 188) is ON when not commanded by right
power module.
RCU 1075 05 Service Alert
Fuel transfer pump (cc# 188) is open circuit.
RCU 1075 06 Service Alert
Fuel transfer pump (cc# 188) is OFF when commanded ON by right
power module.
RCU 1231 09 Service Alert
Message is not arriving on time or missing on local CAN Bus
between the control uni t RCU and right power module.
RCU 1488 03 Service Alert
Threshing speed (cc# 609) signal voltage feedback is out of range -
greater than 4.90 VDC.
RCU 1488 04 Service Alert
Threshing speed (cc# 609) signal voltage feedback is out of range -
less than 0.10 VDC.
RCU 1489 03 Service Alert
Cleaning fan speed (cc# 606) signal voltage feedback is out of range
-greater than 4.90 VDC.
RCU 1489 04 Service Alert
Cleaning fan speed (cc# 606) signal voltage feedback is out of range
-less than 0.10 VDC.
RCU 1490 03 Service Alert
Feeder house (#1 Threshing Cylinder)
speed (cc# 619) signal
voltage feedback is out of range -greater than 4.90 VDC.
RCU 1490 04 Service Alert
Feeder house ( #1 Threshing Cylinder ) speed (cc# 619) signal
voltage feedback is out of range -less than 0.10 VDC.
RCU 1493 12 Service Alert
Tailings monitor system failure. Tailings sensors have read the same
value for 10 seconds and are not full.
MAN141 09/08/15 381