Page #120 background imageLoading...
Page #120 background image
Field Description
Undo change pid parame-
ter
If this field is activated, the PID parameters of the previous opti-
mization are restored
Max. preheat time
This value only takes effect if the machine is connected with Easy-
Net Control Center and if the option "Heatup optimization" of
EasyNet is used.
This value defines how long the used material is allowed to be on
operating temperature without any impairment of the material
characteristics.
Oil temperature
Information
This fields are only shown if an oil temperature sensor is available.
Field Description
Start cooling If the temperature exceeds this limit, oil cooling will be activated.
Stop cooling
If the temperature falls below this limit, oil cooling will be deacti-
vated.
Alarm temp high
If oil temperature exceeds this limit, an alarm will be raised and
the motor will be turned off.
Warn temp high
If the oil temperature exceeds this limit, a warning will be raised.
The monitoring for this temperature is only active in full- and half
automatic mode.
Warn temp low
If the oil temperature falls below this limit, a warning will be raised.
The monitoring for this temperature is only active in full- and half
automatic mode.
Alarm temp low
If the oil temperature falls below this limit, an alarm will be raised.
Changing into full- and half automatic mode is not possible.
Sensor type
Selection of the type of oil temperature sensor (none, J-, K- or L
type).
Oil Pre Heating
Information
If no tank heating is available, the oil can be heated by circulation (pre heat-
ing).
Field Description
Activate pre-heating The preheating function can be activated by this field.
Start oil pre heating
Specification of the minimum oil temperature. If this value is fallen
below, the oil pre heating is activated.
Stop oil pre heating
Specification of the temperature at which the oil pre heating is de-
activated again.
Description of the operating masks KePlast.HMI.KVB
© KEBA 2016
User's manual V3.05120

Table of Contents

Other manuals for Keba Kemro K2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba Kemro K2 and is the answer not in the manual?

Keba Kemro K2 Specifications

General IconGeneral
BrandKeba
ModelKemro K2
CategoryController
LanguageEnglish

Related product manuals