4.8.3 Description of the elements
Slide table / Rotary table minimum profile output
Field Description
Min. profile output in
The minimum profile output (pressure, velocity) for the slide table
in movement is adjusted here. The output in any section of the
profile never falls below this value.
Min. profile output out
The minimum profile output (pressure, velocity) for the slide table
out movement is adjusted here. The output in any section of the
profile never falls below this value.
Min. output rotate
The minimum profile output (pressure, velocity) for the rotary table
movement is adjusted here. The output in any section of the profile
never falls below this value.
Slide table / Rotary table ramp profile output
Field Description
Max. ramp slide in
The maximum ramp (pressure, velocity) for the slide table in
movement is adjusted here.
Max. ramp slide out
The maximum ramp (pressure, velocity) for the slide table out
movement is adjusted here.
Max. ramp rotate
The maximum ramp (pressure, velocity) for the rotary table move-
ment is adjusted here.
Max. ramp lock pin in
The maximum ramp (pressure, velocity) for the lock pin in move-
ment is adjusted here.
Max. ramp lock pin out
The maximum ramp (pressure, velocity) for the lock pin out move-
ment is adjusted here.
Slide table / Rotary table ramps setup mode
Field Description
Slide in
Ramp (pressure and velocity) in setup mode for slide table in
movement is adjusted here.
Slide out
Ramp (pressure and velocity) in setup mode for slide table out
movement is adjusted here.
Rotate
Ramp (pressure and velocity) in setup mode for rotary table move-
ment is adjusted here.
Lock pin in
Ramp (pressure and velocity) in setup mode for lock pin in move-
ment is adjusted here.
Lock pin out
Ramp (pressure and velocity) in setup mode for lock pin out move-
ment is adjusted here.
4.9 Mold Setup Advanced - Tab Mold control
4.9.1 Purpose
This mask is used to setup the data for a mold servovalve.
KePlast.HMI.KVB
Description of the operating masks
© KEBA 2016
User's manual V3.05 55