Screw
Field Description
Max. plast rotation Display and modification of the maximum plast rotation.
Inject
Field Description
Max. speed forward
Display and modification of the maximum velocity forward for the
injection.
Max. speed backward
Display and modification of the maximum velocity backward for
the injection.
With accumulator
The maximum injection speed with the use of an accumulator is
specified here.
This field is only shown if a corresponding accumulator is availa-
ble.
Nozzle
Field Description
Max. speed forward
Display and modification of the maximum velocity for the 'Nozzle
forward' movement.
Max. speed backward
Display and modification of the maximum velocity for the 'Nozzle
backward' movement. T
Slide table
Only visible if a slide table with transducer is used.
Field Description
Max. speed forward
Display and modification of the maximum velocity for the 'Slide
table in' movement.
Max. speed backward
Display and modification of the maximum velocity for the 'Slide
table out' movement.
4.117
Automatic ramp calibration
4.117.1 Purpose
In this mask the automatic ramp identification can be executed during ramp
calibration.
4.117.2 Description of the mask
The maximum ramp and dead time can be identified during ramp calibration
on this mask. The identified values for the ejector, mold, nozzle and inject are
displayed.
Description of the operating masks
KePlast.HMI.KVB
© KEBA 2016
User's manual V3.05228