4.109.3 Description of the elements
Name Description
Points Number of points in the linearization table.
Actual Voltage Displays the actual voltage of the sensor.
Start Index
Since only a maximum of 9 linearization points
can be displayed on the mask, this field serves
for navigation purposes. The input value al-
ways corresponds to the index of the element
displayed first. Example: Value 1: linearization
points 1 to 9 are displayed. Value 17: lineari-
zation points 17 to 25 are displayed, etc.
Modify index
Linearization points can be deleted or added.
The configured index defines which lineariza-
tion point gets deleted resp. after which linea-
rization point a new point gets added.
V / bar
Calibration of the mold pressure sensors is
done by entering the pressure [bar] and the
voltage [V] for each linearization point.
4.110
Calibration pump
4.110.1 Purpose
This mask can be used to manually calibrate the pump pressure and pump
velocity for the selected pump (Tab1 - Tab3). Additionally the minimum and
maximum output voltages for pressure and velocity during the calibration can
be set.
4.110.2 Description of the mask
The manual calibration of a sensor is done by entering values in a linearization
table.
Description of the operating masks KePlast.HMI.KVB
© KEBA 2016
User's manual V3.05214