4.33 Inject Setup Advanced - Tab Inject control
4.33.1 Purpose
This mask is used to set the regulator parameters for the injection unit.
4.33.2 Description of the mask
This mask is divided into the sections:
Inject
Inject pressure limit
Hold
Backpressure
Plasticize
Inject position control
Fig.4-36: Mask "Inject Setup Advanced - Tab Inject control"
4.33.3 Description of the elements
Inject
Field Description
Use PID
When this option is selected, the injection is regulated (PID), oth-
erwise it will be controlled.
P The proportional part for the injection regulator is adjusted here.
I The integral part for the injection regulator is adjusted here.
D The differential part for the injection regulator is adjusted here.