4.33 Inject Setup Advanced - Tab Inject control
4.33.1 Purpose
This mask is used to set the regulator parameters for the injection unit.
4.33.2 Description of the mask
This mask is divided into the sections:
● Inject
● Inject pressure limit
● Hold
● Backpressure
● Plasticize
● Inject position control
Fig.4-36: Mask "Inject Setup Advanced - Tab Inject control"
4.33.3 Description of the elements
Inject
Field Description
Use PID
When this option is selected, the injection is regulated (PID), oth-
erwise it will be controlled.
P The proportional part for the injection regulator is adjusted here.
I The integral part for the injection regulator is adjusted here.
D The differential part for the injection regulator is adjusted here.
Description of the operating masks KePlast.HMI.KVB
© KEBA 2016
User's manual V3.0598