4.63.3 Description of the elements
Field Description
Cycle delay
Here the number of shots can be specified after
which the recording starts (entry of 3, waiting
period is 3 shots).
Cycle interval
The interval between two recordings can be
defined here. The specification is made in
shots. At an interval of 1 every shot is recorded,
at an interval of 2 only every second.
Number of samples
The number of sample-shots to use to calcu-
late the sampled values (e. g. Mean (Sample)
or Stddev(Sample)). If the number of samples
is changed, the sampling is restarted.
Error tolerance
Value in percent, that is used for every recor-
ded variable as error tolerance. The user has
to commit the setting via the Use switch.
Error monitoring
Set to active, if the error monitoring is to be en-
abled for every recorded variable. The user has
to commit the setting via the Use switch.
Warning tolerance
Value in percent, that is used for every recor-
ded variable as warning tolerance. The user
has to commit the setting via the Use switch.
Warning monitoring
Set to active, if the warning monitoring is to be
enabled for every recorded variable. The user
has to commit the setting via the Use switch.
Save PDP data to file
Set to active, to store the recorded process da-
ta protocol in a protocol file.
Protocol error action
Protocol error action to execute, when the pro-
tocol folder is full.
● Continue cycle = continues the production
● Stop cycle = interrupts the production until
protocol folder is emptied
Protocol folder Protocol file storage location
Buttons
Name Description
Variables Opens the SPC variable selection mask
Delete
When this button is pressed the SPC is reset,
which means that all recordings are deleted.
4.64 SPC Variable Setup
4.64.1 Purpose
Change the recorded variables in the Process Data Protocol (PDP) and the
Statistical Process Control (SPC).
Description of the operating masks