4.38.2 Description of the mask
Fig.4-41: Mask "Valve gates - tab setup"
4.38.3 Description of the elements
General settings
Field Description
Valve gate type
The valve gate type can be adjusted here.
● Monostable: Valve gate with one digital output. The valve gate
is opened by setting the digital output and closed by resetting
the digital output.
● Bistable: Valve gate with two digital outputs. The valve gate
is opened with the first digital output and closed with the sec-
ond digital output.
4.39 Nozzle - Tab Profile
4.39.1 Purpose
Settings for the nozzle movement can be done in this mask.
4.39.2 Description of the mask
Within the sections Nozzle forward and Nozzle backward, the pressure and
velocity for the nozzle forward movement and for the nozzle backward move-
ment can be specified. The number of input fields depends if the the nozzle
moves position depending (with limit switch or transducer) or time depending.
The setting if the nozzle moves position or time depending, can be defined in
KePlast.HMI.KVB
Description of the operating masks
© KEBA 2016
User's manual V3.05 107