Mold position control
Field Description
Use position control The position controller for the mold can be activated.
Mold position control Gain
P
The proportional part for the mold position controller is adjusted
here.
Max. control time
Position controlling starts after a mold movement has finished and
stopps after this time value. If this time is set to 0.0 s, the position
controller keeps active until the next mold movement is started.
Force control
Field Description
Gain P
The proportional part for the clamp force controller is adjusted
here.
Gain open loop forward
Open loop gain of mold forward movement for clamp force con-
troller
Gain open loop backward
Open loop gain of mold backward movement for clamp force con-
troller
4.10 Mold height adjust
4.10.1 Purpose
The settings for the mold height adjustment can be done in this mask.
4.10.2 Description of the mask
The mask is divided into the sections General settings, Mold adjust out-
put, Advanced settings and Clamp force monitoring.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 57