4.56.3 Description of the elements
Power
Field Description of the elements
Motor Current motor porwer.
Heating Current heating power.
Sum Sum of the current required power.
Energy
Field Description of the elements
Per shot Displays the consumed energy per shot.
Shot volume
Displays the consumed energy per cm³ of a
shot volume.
Part mass
Displays the consumed energy per gram of the
part mass. For calculation, the correct part
mass has to be entered on mask operating op-
tions.
Part
Displays the consumed energy per part.
Production
Displays the consumed energy of the actual
running production. For calculation, the pro-
duction counter mass must be activated on
mask operating options.
Sum
Displays the consumed total energy.
Reset Resets the actual energy consumption values.
4.57 Energy Chart (by shot)
4.57.1 Purpose
The mask energy chart (by shot) is used to record and display the energy
consumption of the machine for every shot graphically.
Information
The mask is only displayed if the option speed pump is used.
4.57.2 Description of the mask
The energy consumption of the machine for each shot is displayed graphically
in Joule [J]. The [%]- value on the left y- axis shows which area of the chart is
actually displayed. The single shots are displayed on the x- axis of the diagram.
Button Keys fades- in resp. fades- out a legend which shows the actual energy
consumption and its color-coded assignments.
By using the Zoom- buttons it is possible to zoom in and out in inside the
diagram.
KePlast.HMI.KVB
Description of the operating masks
© KEBA 2016
User's manual V3.05 137