Information
These sectors are only displayed when the corresponding options are avail-
able and have been configured.
Fig.4-102: Mask "Maschine equipment tab2''
4.96.3 Description of the elements
Oil filter
Field Description
Oil filter error mode
According to sensor type, this field defines when an oil filter error
is triggered (rising or falling edge).
Oil filter monitor time
The monitoring time for the oil filter is specified here. If the oil filter
signals an error for the time specified here, a corresponding alarm
is triggered
Oil level
Field Description
Oil level error mode
According to sensor type, this field defines when an oil level error
is triggered (rising or falling edge).
Oil level monitor time
The monitoring time for the oil level is specified here. If an oil level
error is signaled for the time specified here, a corresponding alarm
is triggered.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 195