Field Description
Mode
Depending on the selected system variable, different settings are
possible.
● Rising for datatype Bool.
The digital output will be set/reset if the state of the variable
changes from FALSE to TRUE.
● Rising for datatype Real/Integer/Time.
The digital output will be set/reset if the value of the system
variable exceeds a defined threshold.
● Falling for datatype Bool.
The digital output will be set/reset if the state of the variable
changes from TRUE to FALSE.
● Falling for datatype Real/Integer/Time.
The digital output will be set/reset if the value of the system
variable falls below the defined threshold.
● Change
The digital output will be set/reset if the value of the system
variable changes.
Not available for datatype Real and Time.
Threshold
Not available for datatype Bool.
Defines the threshold where a digital output will be set/reset.
Threshold is a time value if the system variable is from datatype
time.
Delay Delays the setting/resetting of a digital output.
Modulo
Defines how often a condition has to be fulfilled in order to set/
reset a digital output.
4.60 Flex IO SystemVariables
4.60.1 Purpose
Shows all system variables that can be configured on FlexIO- mask.
4.60.2 Description of the mask
All system variable of the variable group 'IOParam' are listed.