Field Description
Output
Displays the current heating output (in % of maximum possible
output).
Inc. temp
Here the temperature increase for fast heating of the zone can be
activated. If this function is active the value under Increase tem-
perature in mask "Hotrunner settings" is added to the value speci-
fied for the temperature of the zone.
Standby temperature
In this sector the settings for the set temperature and tolerance limits can be
made which take effect for all hot runners that are displayed on the current
mask.
Field Description
Use
This function is used to hold the temperatures of the heating zones
constantly above the standby temperature. This setting is only ef-
fective with operating mode "PID" of the hot runners.
Temperature Temperature which is hold when function Standby is active.
Power
In this section the power measurements are displayed for this group of zones.
Field Description
Pwr. Power measurement of the actual group of zones.
Curr. Current measurement of the group of zones.
Volt Voltage measurement of the group of zones.
Quick Set
In this sector the settings for the set temperature and tolerance limits can be
made which take effect for all hot runners that are displayed on the current
mask.
Field Description
Set Specifies the set temperature of the hot runners.
Tol+ Specifies the upper tolerance limit.
Tol- Specifies the lower tolerance limit.
Use
Must be activated to copy the values for Set, Tol+ and Tol- to every
hotrunner zone.
4.48 Hot runner Setup
4.48.1 Purpose
In this mask general settings for operating the hot runner system can be speci-
fied.
Description of the operating masks
KePlast.HMI.KVB
© KEBA 2016
User's manual V3.05124