Fig.4-21: Mask "Ejector setup"
4.18.3 Description of the elements
General settings
Field Description
Ejector stroke
Stroke of the ejector depending on its starting position (configured
in input field Ejector offset).
Ejector offset
Actual starting position of the ejector, measured by its distance
from its absolute zero position (offset).
Set ejector zero pos. Sets the ejector offset to the current ejector position.
Eject during mold open
If set, the ejector will be moved during mold open.
If the machine is equipped with only one hydraulic pump for the
mold- and ejector movement, both movements share the pump
output. A pump output to the ejector only happens as long as the
mold movement is active.
Ejector forward start posi-
tion
Mold Position where ejector starts parallel to mold open move-
ment.
Mold check position
● Ejector can only move forward if the actual mold position is
greater than the set mold check position.
● Ejector has to be at rear end position if mold position is less
than the set mold check position.
● If value is set to 0, the monitoring is deactivated
Override ejector safety
Movement of ejector is even allowed, if mold, core and other ejec-
tors are not in the correct position.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 73