4.31 Inject Setup Advanced - Tab1
4.31.1 Purpose
Additional parameters for injection can be configured within this mask.
4.31.2 Description of the mask
For the inject movement the minimum profile outputs, maximum ramp settings
and pump and valve delay times can be set.
Fig.4-34: Mask "Inject setup advanced tab1"
4.31.3 Description of the elements
Minimum profile output
Field Description
Min. profile output inject
The minimum profile output (pressure, velocity) for the inject
movement is adjusted here. The output in any section of the profile
never falls below this value.
Ramp profile output
Field Description
Max. ramp inject
The maximum ramp (pressure, velocity) for the the inject move-
ment is adjusted here.
Max. ramp hold
The maximum ramp (pressure, velocity) for the the hold movement
is adjusted here.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 95