Unit setup
Field Description
Plasticize velocity unit
Selection of the unit that is used for plasticize velocity. Possible
units are
● rpm: screw rotations per minute.
● %: percent value of maximum possible screw rotation.
Maximum movement time
Field Description
Inject
The left field Actual displays the current time for the inject move-
ment. The maximum permitted time for the incect movement
specified in field Limit. If this time is exceeded an alarm will be
triggered and the cycle is stopped. The difference between the two
values is shown in the right field Differ.
Plasticize
The left field Actual displays the current time for the plasticize
movement. The maximum permitted time for the plasticize move-
ment specified in field Limit. If this time is exceeded an alarm will
be triggered and the cycle is stopped. The difference between the
two values is shown in the right field Differ.
Decompression
The left field Actual displays the current time for the decompres-
sion movement. The maximum permitted time for the decompres-
sion movement specified in field Limit. If this time is exceeded an
alarm will be triggered and the cycle is stopped. The difference
between the two values is shown in the right field Differ.
Movement start delay
Field Description
Inject delay The delay time for the inject movement is adjusted here.
Plasticize delay The delay time for the plasticize movement is adjusted here.
Decompression before
The delay time for the decompression movement before plasticize
is adjusted here.
Decompression after
The delay time for the decompression movement after plasticize
is adjusted here.
Setup mode output
Field Description
Setup mode output inject
Pressure and velocity output for the inject movement in setup
mode.
Setup mode output plasti-
cize
Pressure and velocity output for the plasticize movement in setup
mode.
Setup mode output decom-
pression
Pressure and velocity output for the decompression movement in
setup mode.
Description of the operating masks KePlast.HMI.KVB
© KEBA 2016
User's manual V3.0594