4.7 Mold Setup Advanced - Tab1
4.7.1 Purpose
Additional parameters for the mold can be configured within this mask.
4.7.2 Description of the mask
For the mold movement the minimum profile outputs, maximum ramp settings,
pump and valve delay times and settings for mold height adjustment can be
set.
Fig.4-9: Mask "Mold setup advanced tab 1"
4.7.3 Description of the elements
Minimum profile output
Field Description
Min. profile output close
The minimum profile output (pressure, velocity) for the mold close
movementis adjusted here. The output in any section of the profile
never falls below this value.
Min. profile output open
The minimum profile output (pressure, velocity) for the mold open
movement is adjusted here. The output in any section of the profile
never falls below this value.
Description of the operating masks KePlast.HMI.KVB
© KEBA 2016
User's manual V3.0552