4.24.3 Description of the elements
Core ramp manual output
Field Description
Ramp core in
The maximum ramp (pressure, velocity) for the the core in move-
ment is adjusted here.
Ramp core out
The maximum ramp (pressure, velocity) for the the core out move-
ment is adjusted here.
Core ramp setup mode
Field Description
Ramp core in
Ramp (pressure and velocity) in setup mode for core in movement
is adjusted here.
Ramp core out
Ramp (pressure and velocity) in setup mode for core out move-
ment is adjusted here.
Core delay times
Field Description
Core in delay
Field Pump on specifies the time that is waited between the start
of the core in movement and the activation of the hydraulic pump.
Field Valve off determines the time that is waited between the end
of the core in movement and the closing of the control valve in
order to release the remaining pressure.
Core out delay
Field Pump on specifies the time that is waited between the start
of the core out movement and the activation of the hydraulic pump.
Field Valve off determines the time that is waited between the end
of the core out movement and the closing of the control valve in
order to release the remaining pressure.
4.25 Core Ramp Adjust
4.25.1 Purpose
This mask is used to adjust ramp values for the mold during cores are moving
in and out.
4.25.2 Description of the mask
For every core, ramp values in % for the mold movement can be set. Depend-
ing on the configured ramp setting the corresponding ramp duration for the
movement is calculated.
KePlast.HMI.KVB
Description of the operating masks
© KEBA 2016
User's manual V3.05 85