Field Description
Mold gate supervision time
This input field is only visible if two digital inputs (safety gate open
and safety gate closed) are configured. If both digital inputs have
the same state for this set time, the application will trigger an alarm.
This alarm can only be confirmed after the safety gate was detec-
ted once as opened and once as closed.
Light curtain
WARNING!
The system (hardware and software) only meets category B according to
EN ISO 13849-1. Thus it is not intended for usage in safety-relevant control ap-
plications in the field of personal safety (e.g. emergency stop).
To implement potentially necessary safety-relevants control tasks, always use
additional external safety devices according to EN ISO 13849-1 that are intended
for the particular purpose and meet the necessary functional safety.
For further information see EN ISO 13849-1 and refer to chapter "EC directives
and standards" in the manuals for a list of norms applying to the product.
The safety notices for the installation and commissioning of the product can be
found in the user manuals of the components or in the system manual and must
be read and observed before installation or commissioning.
The user manual must be kept throughout the entire service life of the product.
Field Description
Interrupt reaction
This field is only available if the machien is equipped with a light
curtain instead of a mold safety gate.
The reaction to an interrupt of the light curtain can be set here.
Following modes are possible:
● Stop movements: stop all movements
● Stop movements and open mold: stop all movements and
then star tmold open
Light curtain active
This field is only available if the machine is equipped with a light
curtain instead of a mold safety gate.
This setting can be used to decide during which movements the
light curtain should be checked. Following modes are possible:
● always active: Supervision of the light curtain is always active.
● during table move: Supervision is active during slide table or
rotary table movement
● during mold close: Supervision is active during mold close
movement
● combined: Supervision starts at the beginning of slide table
or rotary table movement and ends after mold close.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 193