Mold adjust output
Field Description
Mold adjust output forward
Specification of Pressure and Velocity for hydraulic mold height
adjustment for mold height forward movement.
This field is only shown with hydraulic mold height adjustment.
Mold adjust output back-
ward
Specification of Pressure and Velocity for hydraulic mold height
adjustment for mold height backward movement.
This field is only shown with hydraulic mold height adjustment.
Advanced settings
This section is only shown, if a clamp force sensor is available.
Field Description
Clamp force
The clamp force that is used for mold height adjustment when us-
ing adjust mode 'Force' is specified in the right field.The left field
displays the last determined clamp force during mold height ad-
justment.
This setting is only active in the Adjust mode "Force".
Clamp pressure
The pressure that is used for mold height adjustment when using
adjust mode 'Pressure' is specified in the right field.
This setting is only active in the Adjust mode "Pressure".
Mold height
The new mold height is specified in the right field. The left field
displays the actual determined mold height.
This setting is only active in adjust mode "Position".
Monitor time
Specification of the maximum duration for the procedure of auto-
matic mold height adjustment. If this time is exceeded an alarm
will be triggered.
Standstill
Time that passes until a standstill during mold height adjustment
forward is detected.
This field is only shown with hydraulic mold height adjustment.
Impulse sensor Indicates the single impulses during mold height adjustment.
Single impulse timeout Specification of the maximum duration between two impulses.
Clamp force monitoring
This section is only shown, if a clamp force sensor is available.
Field Description
Monitor clamp pressure Activates clamp force monitoring.
Clamp force tolerance
Setting a tolerance for the clamping force. If this tolerance is ex-
ceeded, an alarm is triggered.
Mold adjust during produc-
tion
If activated, at the end of each production cycle the mold height
gets adjusted automatically if the actual clamp force is greater or
lower than the allowed clamp force range (set clamp force +/- the
configured clamp force tolerance).
Mold height is always adjusted by one gear per production cycle
if clamp force it out of tolerance.
KePlast.HMI.KVB Description of the operating masks
© KEBA 2016
User's manual V3.05 59