Airvalves
Field Description
Mode
Operating mode of an air valve with the following options:
No: Air valve deactivated.
After charge: Air valve becomes active after charging.
After mold open: Air valve becomes active after mold open.
After ejector: Air valve becomes active after ejection of fin-
ished part..
During mold open: Air valve is active during mold open.
Before charge: Air valve becomes active before charging.
After inject: Air valve becomes active after inject.
During mold close: Air valve becomes active during mold
close.
Mold position
Once the position has been reached and the waiting time specified
under "Delay Time" has passed, the corresponding air valve is
activated.
This setting is only active during operating modes 'During mold
open', 'During mold close' and 'Before charge'.
Delay time
Time between the end of the step specified under "Mode" and the
activation of the corresponding air valve.
This setting is deactivated during 'Off' mode.
Time
On time of the corresponding air valve.
This setting is deactivated during 'Off' mode.
Ejector settings
Field Description
Ejector mode
These modes are available:
No: Ejector is deactivated
Hold: This ejector mode is only available for operating mode
'semi-automatic'. The Ejector stays in front end position at the
end of every production cycle.
Continous: The ejector moves automatically between front
and rear end position. The number of sequences (one se-
quence equals a forward and backward movement) per pro-
duction cycle can be set in field Shake counter.
Shake: The ejector moves automatically to front end position
and then backward for the time that is set in field Shake back-
ward time. The number of sequences (one sequence equals
a forward and backward movement) per production cycle can
be set in field Shake counter.
Shake counter
Number of sequences (one sequence equals a forward and back-
ward movement) for the ejector for each production cycle. This
setting is only valid for the ejector modes "Continuous" and
"Shake".