Field Description
Control out
Operating mode of the core during 'Core out' with the following
options:
Before open: Core is extracted prior to the opening of the
mold.
During open: Core is extracted during opening of the mold.
Therefore the mold is stopped, the core moves out and the
mold closes afterwards to its end position. If option 'Cores par-
allel to mold' is set in Core parameters mask, the mold is not
stopped and the core moves parallel to the opening of the
mold.
After open: Core is extracted after opening of the mold.
Hold The core is held forward with pressure after entering.
In / Out Shows if the core is in front end position or rear end position.
Operation mode
These modes can be selected:
Count: Core movement follows the number of Screw
counts set for the core transducer.
Time: Core movement follows the duration set under Time.
Limit: Core monitoring is done by limit switch.
Pressure Set pressure for core movement.
Velocity Set velocity for core movement.
Act. pos (Core in)
Position of the mold at which the core enters. This setting becomes
only active in the entry mode "During close".
Act. pos (Core out)
Position of the mold at which the core is extracted. This setting
becomes only active in extraction mode 'During open'.
Mon. pos (Core in)
If the 'Core in' movement is executed parallel to a movement of
the mold, the core movement must have concluded at the mold
position here specified. Otherwise the mold movement gets stop-
ped at this position until the core movement has finished. After-
wards the mold continues moving.
Mon. pos (Core out)
If the 'core out' movement is executed parallel to a movement of
the mold, the core movement must have concluded at the mold
position here specified. Otherwise the mold movement gets stop-
ped at this position until the core movement has finished. After-
wards the mold continues moving.
Time
Core movement follows the time set for Core In resp. Core out
movement.
This setting is only acitve in the core's mode Time.
Screw count
Number of impulses of the core screw transducer during Core In
resp. Core out movement.
This setting is only active in the core's mode Count.
Priority (Core in)
If several core movements are executed at the same time (e.g.
prior to closing), the sequence for core move-ment is set in this
field. The core with the lowest value for Prio core in is moved in
first.
Priority (Core out)
If several core movements are executed at the same time (e.g.
prior to opening), the sequence for core move-ment is set in this
field. The core with the lowest value for Prio core out is moved out
first.