NTP-008: Circuit Order 365-575-102
Page 8 of 12 Issue 8.0, July 2002
9. Select the other receive fiber (change the 0-db
lightguide buildout as necessary) and connect to
the appropriate RCVR circuit pack. For example,
select line 1W of the East node to be connected
to line 1E of the "new node".
DLP-512
10. At the CIT, select FAULT-Retrieve-Alarm
command to obtain an Active Alarms and Status
Report and verify an incoming OC-48 LOS
condition does not exist for either the 1E or 1W
receiver at the "new node".
—
11. Connect the transmit fibers (change the
lightguide buildout as necessary) to the
appropriate TRMTR circuit pack. For example,
line 1W at the "new node" (to be connected to the
West node) and line 1E (to be connected to the
East node).
DLP-512
12. Instruct the technician at the West node to:
a. Change the lightguide buildout as
necessary on the 1E receive fiber.
b. Connect it to 1E RCVR circuit pack.
c. Verify the RCVR (line 1E) does not
show an incoming OC-48 LOS condi-
tion by obtaining an Active Alarms
and Status Report at the CIT located
at the West node.
—
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish