NTP-008: Circuit Order 365-575-102
Page 12 of 12 Issue 8.0, July 2002
Circuit Order: NTP-008---+---Acceptance: NTP-006
|---Acceptance: NTP-011
|---TAD-100
|---DLP-536
|---DLP-512
|---DLP-524
19. Instruct the technician at the West node to verify
that the NE ACTY LED is off at the user panel. An
alternative method is to log in to the "West node"
and execute the FAULT-Retrieve-Alarms
command to verify that there are NOT any active
alarms.
—
20. Instruct the technician at the East node to verify
that the NE ACTY LED is off at the user panel. An
alternative method is to log in to the "East node"
and execute the FAULT-Retrieve-Alarms
command to verify that there are NOT any active
alarms.
—
21.
NOTE:
Incorrectly provisioned source node TID and/or destination node
TID can result in a service outage under certain multiple failure
conditions.
If required, enter any tributary-to-slot (drop) and/or
slot-to-tributary (add) cross-connections at the
"new node".
DLP-536
22.
NOTE:
Incorrectly assigned node IDs can
result in irregularities of protection
switching.
Perform the Ring Reset procedure to allow correct
node IDs to be reassigned.
Operation: NTP-012
23. STOP! YOU HAVE COMPLETED THIS
PROCEDURE.
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish