365-575-102 CircuitOrder:
Issue 8.0, July 2002 Page 1 of 8
NTP-009
Delete a Node From an In-Service 2-Fiber Ring
Network
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO
1. Overview: This procedure is used to delete an FT-2000 OC-48
Add/Drop-Rings Terminal (Node To Be Deleted) from an existing and
in-service 2-fiber ring network. The Node To Be Deleted may be an
add/drop-rings terminal with or without an FT-2000 Lightwave Booster
Amplifier (FT-LBA). The procedure is written from the Node To Be Deleted
perspective although action is required at two other nodes. The Node To Be
Deleted is located between two operational nodes (called the West Node and
East Node).
Required Test Equipment and Personnel:
• Craft Interface Terminal (CIT)
• Wrist Strap
• Appropriate Optical LBOs
• Technical assistance at two other nodes.
!
WARNING:
Unterminated optical connectors may emit invisible laser radiation. Eye
damage may occur if beam is viewed directly or with improper optical
instruments. Avoid direct exposure to beam.
!
CAUTION:
Use a static ground wrist strap whenever handling circuit packs or
working on an FT-2000 terminal to prevent electrostatic discharge
damage to sensitive components. See "Electrostatic Discharge (ESD)
Considerations" in Trouble Clearing: TAD-100.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish