NTP-009: Circuit Order 365-575-102
Page8of8 Issue8.0,July2002
Circuit Order: NTP-009---+---TAD-100
|---DLP-5l2
15.
NOTE:
Refer to Figure 5. The forced switch at the East Node can now be
reset.
Instruct the technician at the East Node to
enter FAULT-Switch-Line:1W:Reset
command at the CIT. The line switch may
cause traffic hits.
—
16.
NOTE:
Incorrectly assigned node IDs can result in irregularities of protection
switching.
Perform the Ring Reset procedure to
allow correct node IDs to be reassigned.
Operation: NTP-012
17.
NOTE:
The Node To Be Deleted has been deleted from the ring network.
Instruct the technician at the West Node to
verify that the NE ACTY LED is off at the
user panel.
—
18. Instruct the technician at the East Node to verify
that the NE ACTY LED is off at the user panel.
—
DOITEMSBELOWINORDERLISTED....... FORDETAILS,GOTO