NTP-011: Circuit Order 365-575-102
Page4of4 Issue8.0,July2002
Circuit Order: NTP-011---+---TAD-100
|---DLP-501
|---DLP-511
|---DLP-514
|---DLP-536
|---DLP-542
14. At the CIT, select
CONFIGURATION-Delete-Assignment-DCC
to remove the DCC assignment; and repeat the
CONFIGURATION-Delete-Assignment-DCC
command for each DCC channel to be removed.
DLP-542
15. After the rings are separated, it is possible that a
DSNE not reachable and/or NE status
communication failure condition(s) may be
generated. To clear this, assign a DSNE
(TAP-137)andAGNE(TAP-172) in the ring that
contains the alarms.
The OC-3/IS-3 circuit pack(s) has been
removed.
—
16. STOP! YOU HAVE COMPLETED THIS
PROCEDURE.