365-575-102 Operation: NTP-003
Issue 8.0, July 2002 Page 3 of 6
9.
!
CAUTION:
Incorrectly provisioned source node TID and/or destination node TID
can result in a service outage under certain multiple failure conditions.
Enter the required cross-connection(s) as
necessary. Use the
CONFIGURATION-Enter-Crossconnection
-STS3 (or STS1) command to make a
cross-connection.
DLP-536
10. This step is optional. If the cross-connection just made was to a slot
containing an OC-3 circuit pack, you may want to provision a DCC
assignment to establish DCC connectivity with the NE at the other end of the
OC-3 line.
You may enter/change a DCC assignment on an
OC-3 line.
DLP-542
11. At the CIT, select
CONFIGURATION-Retrieve-Crossconnect
ion-STS3 (or STS1) and execute to obtain
an STS3 (or STS1) Cross-Connection Map
Report. Section 11 shows examples of reports.
—
12. Verify that the cross-connections in the report
match those in the operation instructions.
—
13. This step is optional. If the cross-connection just deleted was to a slot
containing an OC-3 circuit pack, you may want to provision a DCC
assignment to remove DCC connectivity with the network element at the
other end of the OC-3 line.
You may delete a DCC assignment on an OC-3
line.
DLP-542
14. Discontinue the login at the secondary node.
(To discontinue a remote login, refer to
DLP-524.)
—
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO