365-575-102 Trouble Clearing: TAP-103
Issue 8.0, July 2002 Page 3 of 4
NOTE:
If the local TID appears in the Network Alarms Report and is among the group of
entries with the highest alarm level, the trouble condition is first cleared at the
local NE before proceeding with trouble clearing at another NE.
9.Isthelocal FT-2000 NE (TID) in the group with the highest alarm level?
If YES, then continue with Step 21.
If NO, then continue with Step 10.
NOTE:
Trouble clearing begins with the topmost entry in the report.
NOTE:
The trouble to be cleared is at a remote FT-2000 or DDM-2000 NE.
Remember, when the following procedures refer to the local CIT, that it is really
logged in to a remote NE and that any corrective action will apply to the remote
NE.
10. Press the CIT function key F2, labeled REMOTE.
11. Referring to the topmost entry in the Network Alarms Report obtained in Step
4 and using the TID, log in to the remote NE.
Reference: DLP-524
12. Were you able to log in to the remote NE?
If YES, then continue with Step 13.
If NO, then continue with Step 19.
NOTE:
You may require assistance at the remote FT-2000 or DDM-2000 NE to replace
a circuit pack(s) or to observe LEDs.
13. Is the remote NE an FT-2000 NE or a DDM-2000 NE?
If FT-2000 NE, then continue with Step 14.
If DDM-2000 NE, then continue with Step 16.
14. Clear the particular condition at the remote FT-2000 NE.
Reference: TAP-102
15. STOP! YOU HAVE COMPLETED THIS PROCEDURE.