TAP-113: Trouble Clearing 365-575-102
Page2of4 Issue8.0,July2002
6. Are software releases identical?
If YES, then go to Step 8.
If NO, then continue with Step 7.
7. Install identical software into the SYSMEM circuit pack that is running in the
FT-2000.
Reference: Operation: NTP-002
8. At the CIT, select FAULT-Reset and execute.
9. Wait 10 minutes or until the MJ LED is off at the user panel, whichever comes
first. Reset takes approximately 10 minutes but some user panel LEDs flash
and relays click in about a minute indicating that reset has started.
10. At the CIT, select FAULT-Retrieve-Alarm to obtain an Active Alarm and
Status Report.
11. Does the SYSCTL failure or SYSMEM failure appear under the
Description column of the report?
If YES, then continue with Step 12.
If NO, then go to Step 17.
12. Reinstall the SYSMEM circuit pack that was removed in Step 2.
NOTE:
For circuit pack and software compatibility, refer to Table 7-1 in Section 7,
"Circuit Pack Description."
13. Remove the SYSCTL circuit pack and install a replacement circuit pack having
the same or a higher series number. For example, an LAA23 with series num-
ber S1:2 is the same series number as S1:4. The 2 and 4 refer to minor
changes within series 1.
Reference: DLP-514
14. Wait 10 minutes or until the MJ LED is off at the user panel, whichever comes
first.
15. At the CIT, select FAULT-Retrieve-Alarm to obtain an Active Alarm and
Status Report.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish