TAP-114: Trouble Clearing 365-575-102
Page2of4 Issue8.0,July2002
2. Referring to the Active Alarms and Status Report on the CIT screen, are any
other conditions indicated?
If YES, then go to TAP-102 to clear the remaining condition(s), ignoring
the condition that sent you here.
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
3. Use the CIT to clear the indicated condition by performing the function listed in
Table A.
4. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
Table A - Determine Command for Condition
Condition To Be Cleared Perform Function
inhibit alarms-office alarms FAULT-Allow-Alarm-All
inhibit alarms-parallel telem
inhibit alarms-X.25
line forced switch FAULT-Switch-Line-All-Reset
line forced switch at far end
line forced switch at near end
line lockout
line lockout at far end
line lockout at near end
line manual switch
line manual switch at far end
line manual switch at near end
line switch inhibit
line switch inhibit - far end
line switch inhibit - near end
non-preemptible protn access
preemptible protn access
OC3 forced switch at far end FAULT-Switch-<LS type>-All-Reset
OC3 forced switch at near end
OC12 forced switch at far end
OC12 forced switch at near end
OC3 inhibit at near end
OC12 inhibit at near end
OC3 lockout at far end
OC3 lockout at near end
OC12 lockout at far end
OC12 lockout at near end