TAP-115: Trouble Clearing 365-575-102
Page8of8 Issue8.0,July2002
NOTE:
After clearing the condition identified in Step 36, continue the trouble clearing
procedure using TAP-102 at the network element that initially reported the
OC3/OC12 auto switch at near end and/or OC3/OC12 auto switch
at far end condition.
39. Find the condition identified in Step 36 in Table A of TAP-102 andgotothe
indicated TAP to clear that condition (ignoring the OC3/OC12 auto switch
at near end and/or OC3/OC12 auto switch at far end condition
throughout the remainder of the trouble clearing procedure).
40. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
NOTE:
An OC3/OC12 auto switch will remain in effect for a provisioned interval (the
Wait To Restore interval) after the cause of the switch is cleared. You can use
the CONFIGURATION-Retrieve-Protection-Low Speed command to
determine the provisioned value of the Wait To Restore interval.
41. Wait for the provisioned Wait To Restore interval to expire or until the NE
ACTY LED goes off, whichever comes first.
42. Is the NE ACTY LED off?
If YES, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.
If NO, then follow local maintenance procedures to clear what appears to
be trouble with the OC-3/OC-12 line. You may consult the appropriate
maintenance support organization for further technical assistance.
43. STOP! YOU HAVE COMPLETED THIS PROCEDURE.