TAP-123: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
5. Did the FAULT LED on the replacement circuit pack go off?
If YES, then continue with Step 6.
If NO, then go to TAP-116.
6. Is the NE ACTY LED lighted?
If YES, then go to Trouble Clearing: IXL-001.
If NO, then STOP! YOU HAVE COMPLETED THIS PROCEDURE.