TAP-136: Trouble Clearing 365-575-102
Page2of4 Issue8.0,July2002
If NO, then continue with Step 16.
8. If the bay is still in service, remove the LNCTL circuit pack.
9. Remove the SYSMEM circuit pack and install a replacement circuit pack hav-
ing the same or a higher series number. For example, a series number S1:2 is
the same series number as S1:4. The 2 and 4 refer to minor changes within
series 1.
Reference: DLP-514
10. Wait 10 minutes. (If an Active Alarms and Status Report is obtained during
this time and the Description Column shows a reset in progress condition,
don't worry because this is a normal software download operation.)
11. Does one or both of the following conditions exist?
a. The NE ACTY and/or FE ACTY LED are lighted.
b. The office alarm(s) is off.
If YES, then continue with Step 19.
If NO, then continue with Step 12.
12. Reinstall the original SYSMEM circuit pack removed in Step 9.
Reference: : DLP-514
13. Remove the SYSCTL circuit pack and install a replacement circuit pack having
the same or a higher series number. For example, a series number S1:2 is the
same series number as S1:4. The 2 and 4 refer to minor changes within
series 1.
Reference: DLP-514
14. Wait 10 minutes.
15. Does one or both of the following conditions exist?
a. The NE ACTY and/or FE ACTY LED are lighted.
b. The office alarm(s) is off.
If YES, then continue with Step 19.
If NO, then contact your local maintenance support group for a higher
level of technical assistance.
16. Install a replacement SYSMEM and/or SYSCTL circuit pack in the appropriate
slot(s).
Reference: DLP-514

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish