TAP-162: Trouble Clearing 365-575-102
Page2of2 Issue8.0,July2002
6. Compare the actual TID obtained in Step 3 with the provisioned TID obtained
in Step 5 and identify any inconsistencies between the actual and provisioned
node TIDs.
7. Do the actual TIDs match the provisioned TIDs?
If NO, then continue with Step 8.
If YES, then continue with Step 12.
8. Log in to the node with the TID inconsistency. If a remote login is required and
you need additional help, refer to DLP-524.
9. At the CIT, select CONFIGURATION-Enter-Crossconnection-STS3 (or
STS1) command to correct the problem (invalid source/destination provision-
ing).
10. If remotely logged in to the node (network element), log out.
11. STOP! YOU HAVE COMPLETED THIS PROCEDURE.
12. Log in to the node with the missing cross-connection. If a remote login is
required and you need additional help, refer to DLP-524.
13. At the CIT, select CONFIGURATION-Enter-Crossconnection-STS3 (or
STS1) command to correct a missing secondary source cross-connection for
DRI circuit.
14. If remotely logged in to the node (network element), log out.
15. STOP! YOU HAVE COMPLETED THIS PROCEDURE.