Operations Interfaces
6-26 Issue 8.0 July 2002
ENTER-ROLL (ENT-ROLL-rr)†—performs a 1-way roll of an STS-3 or STS-1 (Release 7
and later) cross-connection
ENTER-SYNCHRONIZATION (ENT-SYNCN)§§ — provisions the synchronization mode.
ENTER-SYSTEM (ENT-SYS)†—sets network element name and other system level
parameters
ENTER-STS1 (ENT-STS1)‡—sets user-settable strings to the transmit and receive path
trace fields
ENTER-USER-SECURITY (ENT-USER-SECU)* — enters the security parameters
associated with a user
ENTER-rr (ENT-rr)†—provisions various parameters of low speed ports and slots
INHIBIT-MESSAGE (INH-MSG)* — inhibits transmission of all autonomous TL1 messages,
office alarms, and/or parallel telemetry from a network element
INITIALIZE-REGISTER (INIT-REG)* — initializes all current day and/or current 15-minute
performance-monitoring storage registers
INITIALIZE-SYSTEM (INIT-SYS)* — initializes (resets) provisionable parameters to their
original value and restarts the network element software
OPERATE-ALARM CUTOFF (OPR-ACO)* — operates alarm cutoff to silence the audible
office alarms
OPERATE-EXTERNAL CONTROL (OPR-EXT-CONT)§—operates an external
miscellaneous discrete control output
OPERATE-LOOPBACK (OPR-LPBK-rr)†—operates low speed (DS3, EC-1, OC-3, and
OC-12) or high speed (OC-48) loopback
OPERATE-PROTECTION SWITCH-OC3 (OPR-PROTNSW-OC3)* — operates OC-3 line
protection switching
OPERATE-PROTECTION SWITCH-OC12 (OPR-PROTNSW-OC12)§§ — operates OC-12
lineprotectionswitching
OPERATE-PROTECTION SWITCH-OC48 (OPR-PROTNSW-OC48)†—operates OC-48
lineprotectionswitching
OPERATE-PROTECTION SWITCH (OPR-PROTNSW-rr)†—operates STS-3 tributary
protection switching
OPERATE-SYNCHRONIZATION SWITCH (OPR-SYNCNSW)†—operates synchronization
reference protection switching
RELEASE-EXTERNAL CONTROL (RLS-EXT-CONT)§—releases an external
miscellaneous discrete control output

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish