Administration and Provisioning
Issue 8.0 July 2002
8-101
Operations (Contd)
- Port Security (Contd)
Baud Rates
CIT (DCE) (TL1 Protocol)*** 1200,2400,4800,[9600]
CIT (DTE) (TL1 Protocol)*** 1200,2400,4800,[9600]
X.25 Channel Type*** Switched, Permanent
[No Original Value]
OS Type***
X.25 PVC #1 [maint.], memry-admin
cmd-resp,other
X.25 PVC #2 maint., memry-admin CIT SECURITY-Set- SECURITY-Retriev
e-
[cmd-resp],other Security Port Security Port
X.25 SVC #1-#6 maint., memry-admin
[cmd-resp],other,none
SVC Calling Address***
X.25 SVC #1-#6
15 or Less Numeric Characters
Inactivity Timeout††† 0-999 Minutes [15]
Logins 1-100** [ATT01 or ATT††]1to10
Alphanumeric Characters
[luc01
or
luc02****]
1to10
CIT SECURITY-
Set-Login
[ENT-USER-SECU]
SECURITY-Retriev
e-Login
[RTRV-USER-SECU]
Password [FT-2000‡‡]
6to10Characters
,
(at least 1 numeric character
and 1 symbolic character)
CIT SECURITY-Set-
Password
[ED-PID]
None
User Privilege Reports Only, [General] CIT SECURITY-Set-Lo
gin
[ENT-USER-SECU]
SECURITY-Retriev
e-Login
[RTRV-USER-SECU]
Visitor Login*** Yes, [No] CIT SECURITY-Set-Lo
gin
[ENT-USER-SECU]
SECURITY-Retriev
e-Login
[RTRV-USER-SECU]
- Incoming Signal Alarm Delay 0-120 Seconds [2] CONFIGURATION- CONFIGURATION-
- Alarm Clear Delay 0-120 Seconds [10] CIT Set- Retrieve-
- Tributary Reporting**** NO, NR, NA, MN, MJ, CR Attribute-Alarm
[SET-ATTR-ALM]
Attribute-Alarm
[RTRV-ATTR-ALM]
- User-Settable Miscellaneous
Discretes CONFIGURATION- CONFIGURATION-
Description of Control ["Control
n
"] ≤
26 Characters
CIT Set- Retrieve-
Outputs 1-4 Attribute-Contr
ol
[SET-ATTR-CONT]
Attribute-Contro
l
[RTRV-ATTR-CONT]
See footnotes at end of table.
Table 8-5. Provisionable Parameters (FT-2000 OC-48 Add/Drop-Rings Terminal) (Contd)
Parameter Options [Original Value] Method
CIT-PC Input
[TL1 Command]
CIT-PC Report
[TL1 Report]