Administration and Provisioning
8-102 Issue 8.0 July 2002
Operations (Contd)
- User-Settable Miscellaneous (Contd)
Description of ["Environment
n
"] CONFIGURATION- CONFIGURATION-
Environmental Inputs 1-16 ≤
26 Characters
CIT Set-Attribute Retrieve-Attribu
te
Environmental Input CR, MJ, [MN], NA, NR Environment Environment
Alarm Level [SET-ATTR-ENV] [RTRV-ATTR-ENV]
- Date YY-MM-DD [70-01-01]
- Hours 0-23 [0]
- Minutes 0-59 [0] CIT CONFIGURATION- CONFIGURATION-
- Seconds 0-59 [0] Set-Date Retrieve-Date
- Standard Time Zone [
blank
] ≤
3 Letter Characters
[ED-DAT] [RTRV-HDR]
- Start Daylight Savings Date MM-DD [01-01]
- Stop Daylight Savings Date MM-DD [01-01]
- Daylight Savings Time Zone [
blank
] ≤
3 Letter Characters
Line Identification
- Line Name 1E, 1W Automatic None CONFIGURATION-
Retrieve-OC48
Line Protection Switching
- Signal Degrade Threshold 10
-5
,[10
-6
], 10
-7
,10
-8
,10
-9
CIT CONFIGURATION-S
et-OC48
CONFIGURATION-Re
trieve-OC48
Slot State Provisioning FAULT-
- All Slots EQ, [AUTO] Automatic None Retrieve-State
Low-Speed Protection Switching
- Protection Switching Priority [Low], High CIT CONFIGURATION- CONFIGURATION-
(Service) Set-Low Speed Retrieve-
[ENT-rr] Low Speed
[RTRV-rr]
- Configuration [0xN], 1xN Automatic None FAULT-
Retrieve-State
- Wait to Restore* 0-12 Minutes [5] CIT CONFIGURATION-S
et-Protection-L
ow Speed
CONFIGURATION-Re
trieve-
Protection-Low
Speed
Performance Monitoring
- Start Time*** 0-23 [0] CIT PERFORMANCE- PERFORMANCE-
Set-PM-Stime Retrieve-PM-Stim
e
- DS3 PM Mode*** [P-bit], F&M-bit CIT PERFORMANCE- PERFORMANCE-
Set-PM Mode-T3 Retrieve-PM
Mode-T3
See Footnotes at end of table
Table 8-5. Provisionable Parameters (FT-2000 OC-48 Add/Drop-Rings Terminal) (Contd)
Parameter Options [Original Value] Method
CIT-PC Input
[TL1 Command]
CIT-PC Report