Craft Interface Terminal Usage
Issue 8.0 July 2002
11-33
CONFIGURATION-
Set
-OC3 Provisions the "0x1"/"1+1" protection mode,
severity of the alarm assigned to the OC3
failures, the signal degrade threshold, and the
AU-4 S bit.
CONFIGURATION-
Set
-OC12 Provisions the 0x1/"1+1" protection mode,
severity of the alarm assigned to the OC12
failures, the signal degrade threshold, and the
AU-4 S bit.
CONFIGURATION-
Set
-OC48 Provisions the signal degrade threshold and the
protection switch priority parameters of an OC-48
line.
CONFIGURATION-
Set
-Path-Trace Provisions the transmit and receive path traces.
PERFORMANCE-
Set
-PM Mode T3 Provisions one of two different methods (either
(a) P-bit processing or (b) F and M-bit adjusted
processing)) for accumulating DS3 path
performance monitoring data.
PERFORMANCE-
Set
-PM Start Time Provisions the start-time for the measurement of
all twenty-four hour performance monitoring
parameters.
PERFORMANCE-
Set
-PM
Threshold-EC1
Provisions the performance monitoring TCA
threshold values for the EC1 data.
PERFORMANCE-
Set
-PM
Threshold-Line
Provisions the performance monitoring TCA
threshold values for the line performance
monitoring data.
PERFORMANCE-
Set
-PM
Threshold-Optics
Provisions by enabling or disabling the automatic
reporting of TCAs for the optical performance
monitoring data.
PERFORMANCE-
Set
-PM
Threshold-Section
Provisions the performance monitoring TCA
threshold values for the section performance
monitoring data.
PERFORMANCE-
Set
-PM
Threshold-STS1
Provisions the performance monitoring TCA
threshold values for the STS1 path performance
monitoring data.
PERFORMANCE-
Set
-PMThreshold-T3 Provisions the performance monitoring TCA
threshold values for the DS3 performance
monitoring data.
CONFIGURATION-
Set
-Protection-Line Provisions these parameters (configuration,
directional, wait to restore, and restoration
protection access) for an OC-48 line. Currently,
only the restoration protection access parameter
can be set which turns off the ACTY and ABN
LEDs for a preemptible protection access line.
Table 11-8. Input (Command) Definitions (Contd)
Selected Input Purpose