Craft Interface Terminal Usage
11-34 Issue 8.0 July 2002
CONFIGURATION-
Set
-Protection-Low
Speed
Provisions the low-speed protection
characteristics for the network element.
SECURITY-
Set
-Security-Network
Element
Provisions (only by the privilege user) the
network element parameters.
SECURITY-
Set
-Security-Port Provisions (only by the privilege user) the port
access parameters.
CONFIGURATION-
Set
-State-EC1 Provisions the memory administrative state of a
low-speed EC1 port.
CONFIGURATION-
Set
-State-OC3 Provisions the memory administrative state of
low-speed OC3 port.
CONFIGURATION-
Set
-State-OC12 Provisions the memory administrative state of
CONFIGURATION-
Set
-State-T3 Provisions the memory administrative state of a
low-speed DS3 port.
CONFIGURATION-
Set
-Synchronization Provisions the synchronization characteristics of
the FT-2000 network.
CONFIGURATION-
Set
-T3 Provisions the characteristics of a DS3 port.
FAULT-
Switch
-Line Makes or breaks the protection switching of an
OC-48 line.
FAULT-
Switch
-Low Speed Makes or breaks the protection switching of the
low-speed slots.
FAULT-
Switch
-OC3 Controls the "1+1" protection switching operation
(OC3 equipped slot pair) according to priority
(reset, lockout of protection, inhibit, forced switch,
and manual switch).
FAULT-
Switch
-OC12 operation Controls the "1+1" protection switching (OC12
equipped slot pair) according to priority (reset,
lockout of protection, inhibit, forced switch, and
manual switch).
FAULT-
Switch
-Path-STS1 Controls the DRI protection switching operation
through external switch requests according to
reset (first) and manual switch (second) priorities.
FAULT-
Switch
-Path-STS3 Controls the DRI protection switching operation
through external switch requests according to
reset (first) and manual switch (second) priorities.
FAULT-
Switch
-Synchronization-
Hardware
Controls the protection switching operation of the
synchronization hardware.
FAULT-
Switch
-Synchronization-Mode Controls the protection switching operation of the
FT-2000 network element timing mode.
FAULT-
Switch
-Synchronization-
Reference
Controls the protection switching operation of the
synchronization timing reference.
Table 11-8. Input (Command) Definitions (Contd)
Selected Input Purpose

Table of Contents