365-575-102 Acceptance: NTP-007
Issue 8.0, July 2002 Page 3 of 4
8. At the CIT, select
CONFIGURATION-Retrieve-Synchronization
and execute to obtain a Synchronization Report for
the local node.
—
9. Verify the report agrees with the engineered data,
particularly the Provisioned Mode. Section 11 shows
example of report.
—
10.
NOTE:
If you are remotely logged in, you will require assistance at the distant node in
order to perform this step.
If required, test office alarm operation. DLP-504
11.
NOTE:
An FT-LBA provides four miscellaneous discrete (environmental) inputs to the
FT-2000 terminal. If the network is so equipped, these inputs are tested
separately in Acceptance: NTP-011.
NOTE:
If you are remotely logged in, you will require assistance at the distant node in
order to perform this step.
If required, check telemetry interfaces.
a. Parallel telemetry
b. Serial telemetry
c. Miscellaneous discrete telemetry
DLP-508
DLP-509
DLP-530
12. Establish a remote login to one of the other FT-2000
add/drop-rings terminals on the FT-2000 ring network.
DLP-524
13. Repeat Steps 6 through 11 for that FT-2000
add/drop-rings terminal.
—
14. Discontinue the remote login. DLP-524
15. Repeat Steps 12 through 14 for each of the remaining
FT-2000 add/drop-rings terminals in the FT-2000 ring
network.
—
DO ITEMS BELOW IN ORDER LISTED . . . . . . . FOR DETAILS, GO TO