365-575-102 Acceptance: NTP-009
Issue 8.0, July 2002 Page 7 of 12
42. Repeat Steps 34 through 36 for each path being
tested.
43. At the FT-2000 primary node P', reset the manual
DRI switch for each path being tested. Use the
FAULT-Switch-Path-STS3-Reset command for
the appropriate line(s) and tributary(s).
44. Verify that there are no alarm or status conditions in
the ring.
45. This completes testing path integrity (Figure 4).
46. This completes testing path integrity (Figure 4) in the
local FT-2000 ring. If the external network is
non-Lucent (another vendor), refer to local
maintenance procedures to test path integrity in that
ring. If the network is a DDM-2000 ring, refer to the
appropriate manual as follows:
63-206-202 for DDM-2000 OC3 for Releases 2 through 7.2
63-206-280 for DDM-2000 OC3 for Release 8 and Higher
63-206-207 for DDM-2000 OC12/OC12 Regenerator for Releases 1
through 3.1
63-206-290 for DDM-2000 OC12 for Release 5 and Higher
47. The local FT-2000 ring has two DRI cross-connections to the outside. Both DRI
cross-connections terminate to external networks.
Verify that there are no alarm or status conditions in
either ring (Figure 5).
48. At the transmit end in the external network (left side),
insert a verifiable signal into each path being tested.
49. At the receive end in the external network (right
side), verify the detection of the inserted signal on
each path being tested.
50. To test path integrity for 2-way paths, repeat Steps
48 and 49 from opposite ends of each path.