Parker EME
Setting up Compax3
192-121102 N04 June 2008 121
Object 175.4: IN3 Offset
Object name
C3.AnalogInput3_Offset
Object No. 175.4 HEDA-channel
no
Access:
Read/write
Valid after:
Immediately
CodeSys object:
no
CodeSys format:
INT
Unit
Increments
Minimum value
n/a
Maximum value
n/a
Remark:
Offset in AD increments
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I16
Object 175.3: IN3 Filter
Object name
C3Plus.AnalogInput3_FilterCoefficient
Object No. 175.3 HEDA-channel
no
Access:
Read/write
Valid after:
VP
CodeSys object:
yes
CodeSys format:
DINT
Unit
us
Minimum value
us
Maximum value
us
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I32
Object 176.11: IN4 Offset
Object name
C3Plus.AnalogInput4_Offset_normed
Object No. 176.11 HEDA-channel
no
Access:
Read/write
Valid after:
Immediately
CodeSys object:
yes
CodeSys format:
REAL
Unit
V
Minimum value
V
Maximum value
V
Remark:
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
C4_3
Object 176.4: IN4 Offset
Object name
C3.AnalogInput4_Offset
Object No. 176.4 HEDA-channel
no
Access:
Read/write
Valid after:
Immediately
CodeSys object:
no
CodeSys format:
INT
Unit
n/a
Minimum value
n/a
Maximum value
n/a
Remark:
Offset in AD increments
CAN No.
-
PD object:
no
Profibus-No. (PNU)
-
Bus format:
I16