Operations and Maintenance Manual Universal Vacuum System
Version 1.2—March 2004 Page 19
PRESSURIZED AIR IN
Connect clean, dry house air (80-120 psi) to the connection marked Clean Dry Air on the
front control panel. The safety lockout valve (265648) is on this line.
The pilot pressure regulator passes air at 80 psi to the purge pressure regulator, and through
solenoid 2 to the three pneumatically operated valves.
INDUSTRIAL WASTE OUT
The drain line is routed to the ½" poly hose connection on the control panel on the front of
the Universal Vacuum. This connection is labeled Industrial Waste. Connect a line from
this ½" fitting to the proper house receptacle.
NOTE: Since Strasbaugh cannot regulate the materials or chemicals used in a customer-
specified process, Strasbaugh is not responsible for injury related to chemicals or materials
that may be used.
VACUUM OUT
Connect vacuum lines to provide vacuum to the equipment you desire. See optional fitting
kits available on drawing 289000T1.