STRASBAUGH, INC.
7AF SECS/GEM Interface Ver. 1.9 February 19, 2002 6-17
Strasbaugh Confidential
6-17
6.42 S2F42 - Remote Command Acknowledge
S2F42 * H<-E
<L [2]
<B [1] HCACK> * Host Command Ack. Code
<L [n]
<L [2]
<A CPNAME> * name of parameter
<B [1] CPACK> * Cmd Param Ack Code
>
...
>
> .
Normal completion returns a zero (0) in HCACK. The number of erroneous parameters "N" in S2F42 will be zero.
A non-zero value for HCACK indicates that the Equipment has rejected the Remote Command. The number of erroneous
parameters "n" can be zero or greater.
HCACK Description
0x00 OK. All normal.
0x01 Invalid command. Equipment rejects command
0x02 Cannot perform now. Equipment rejects command.
0x03
At least one parameter is invalid. Equipment rejects
the command.
0x40 Control State is Local. Equipment rejects command.
0x41
Incorrect Process State for this command. Equipment
rejects command.
CPACK Description
0x01 Invalid parameter name (CPNAME). The CPNAME
is not a valid parameter for this command.
0x02
Illegal parameter value (CPVAL). The parameter
value is out of range.
0x03
Illegal format for parameter (CPVAL). The value for
this parameter does not use the correct SECS-II data
item type.
0x40
Duplicate parameter name. This parameter name
occurred at least twice in the S2F41 command.